Time of flight

For the mass spectrometry technique, see time-of-flight mass spectrometry.

Time of flight (TOF) describes a variety of methods that measure the time that it takes for an object, particle or acoustic, electromagnetic or other wave to travel a distance through a medium. This measurement can be used for a time standard (such as an atomic fountain), as a way to measure velocity or path length through a given medium, or as a way to learn about the particle or medium (such as composition or flow rate). The traveling object may be detected directly (e.g., ion detector in mass spectrometry) or indirectly (e.g., light scattered from an object in laser doppler velocimetry).

results in this equation

for the time of flight of a projectile.

Time-of-flight mass spectrometry

Shimadzu Ion Trap TOF

Time-of-flight mass spectrometry (TOFMS) is a method of mass spectrometry in which ions are accelerated by an electric field of known strength. This acceleration results in an ion having the same kinetic energy as any other ion that has the same charge. The velocity of the ion depends on the mass-to-charge ratio. The time that it subsequently takes for the particle to reach a detector at a known distance is measured. This time will depend on the mass-to-charge ratio of the particle (heavier particles reach lower speeds). From this time and the known experimental parameters one can find the mass-to-charge ratio of the ion. The elapsed time from the instant a particle leaves a source to the instant it reaches a detector.

Ultrasonic and optical time-of-flight flow meters

An ultrasonic flow meter measures the velocity of a liquid or gas through a pipe using acoustic sensors. This has some advantages over other measurement techniques. The results are slightly affected by temperature, density or conductivity. Maintenance is inexpensive because there are no moving parts.

Ultrasonic flow meters come in three different types: transmission (contrapropagating transit time) flowmeters, reflection (Doppler) flowmeters, and open-channel flowmeters. Transit time flowmeters work by measuring the time difference between an ultrasonic pulse sent in the flow direction and an ultrasound pulse sent opposite the flow direction. Doppler flowmeters measure the doppler shift resulting in reflecting an ultrasonic beam off either small particles in the fluid, air bubbles in the fluid, or the flowing fluid's turbulence. Open channel flow meters measure upstream levels in front of flumes or weirs.

Optical time-of-flight sensors consist of two light beams projected into the fluid whose detection is either interrupted or instigated by the passage of small particles (which are assumed to be following the flow). This is not dissimilar from the optical beams used as safety devices in motorized garage doors or as triggers in alarm systems. The speed of the particles is calculated by knowing the spacing between the two beams. If there is only one detector, then the time difference can be measured via autocorrelation. If there are two detectors, one for each beam, then direction can also be known. Since the location of the beams is relatively easy to determine, the precision of the measurement depends primarily on how small the setup can be made. If the beams are too far apart, the flow could change substantially between them, thus the measurement becomes an average over that space. Moreover, multiple particles could reside between them at any given time, and this would corrupt the signal since the particles are indistinguishable. For such a sensor to provide valid data, it must be small relative to the scale of the flow and the seeding density. MOEMS approaches yield extremely small packages, making such sensors applicable in a variety of situations.[5]

High-precision measurements in physics

Usually the tube is praised for simplicity, but for precision measurements of charged low energy particles the electric and the magnetic field in the flight tube has to be controlled within 10 mV and 1 nT respectively.

The work function homogeneity of the tube can be controlled by a Kelvin probe. The magnetic field can be measured by a fluxgate compass. High frequencies are passively shielded and damped by radar absorbent material. To generate arbitrary low frequencies field the screen is parted into plates (overlapping and connected by capacitors) with bias voltage on each plate and a bias current on coil behind plate whose flux is closed by an outer core. In this way the tube can be configured to act as a weak achromatic quadrupole lens with an aperture with a grid and a delay line detector in the diffraction plane to do angle resolved measurements. Changing the field the angle of the field of view can be changed and a deflecting bias can be superimposed to scan through all angles.

When no delay line detector is used focusing the ions onto a detector can be accomplished through the use of two or three einzel lenses placed in the vacuum tube located between the ion source and the detector.

The sample should be immersed into the tube with holes and apertures for and against stray light to do magnetic experiments and to control the electrons from their start.

See also

References

  1. R.G. Kepler (1960). "Charge Carrier Production and Mobility in Anthracene Crystals". Phys. Rev. 119 (4): 1226. Bibcode:1960PhRv..119.1226K. doi:10.1103/PhysRev.119.1226.
  2. M. Weis; J. Lin; D. Taguchi; T. Manaka; M. Iwamot (2009). "Analysis of Transient Currents in Organic Field Effect Transistor: The Time-of-Flight Method". J. Phys. Chem. C. 113 (43): 18459. doi:10.1021/jp908381b.
  3. Cotter, Robert J. (1994). Time-of-flight mass spectrometry. Columbus, OH: American Chemical Society. ISBN 0-8412-3474-4.
  4. Time-of-Flight Techniques For The Investigation Of Kinetic Energy Distributions Of Ions And Neutrals Desorbed By Core Excitations
  5. Modarress, D.; Svitek, P.; Modarress, K.; Wilson, D. (July 2006). "Micro-optical sensors for boundary layer flow studies" (PDF). 2006 ASME Joint U.S.-European Fluids Engineering Summer Meeting.
This article is issued from Wikipedia - version of the 10/4/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.