Argox

Argox is the informal name for a scuba diving breathing gas consisting of argon and oxygen. Occasionally the term argonox has been used to mean the same mix. The blend may consist of varying fractions of argon and oxygen, depending on its intended use. The mixture is made with the same gas blending techniques used to make nitrox, except that for argox, the argon is added to the initial pure oxygen partial-fill, instead of air.

Argox is essentially a theoretical diving gas, being rarely, if ever, used, and usually thought to have no practical applications where its benefits outweigh its drawbacks.

Possible uses

Drysuit inflation

The helium in the breathing gas trimix, which is used to avoid nitrogen narcosis on deep dives, gives the gas a high thermal conductivity compared with air, making it inappropriate for drysuit inflation. Divers breathing trimix with drysuits usually inflate their drysuits with their decompression gas (usually nitrox or oxygen). A few carry yet another small cylinder, dedicated to drysuit inflation, containing argon.[1]

A second class of divers at intermediate depths of 30–45 metres (100–150 ft) which do not require trimix sometimes carry a pony bottle for emergencies, as is taught in many deep diving courses. Such second bottles are often 3 litres, and may be mounted in various ways from tank bracket to sling mounting. This second bottle can be used for argox, if a drysuit is used.

Some argue that an argox blend with oxygen content similar to that of air could be used as a suit inflation gas in place of pure argon, as such a blend would only have a slightly higher thermal conductivity than pure argon, and unlike pure argon, would be breathable in an emergency. However, there are many problems with the use of suit inflation gas as an emergency breathing gas. Argon is a very narcotic gas, meaning that it could only be breathed at comparatively shallow depths above 20 metres (66 ft). However, in an emergency this is enough for adequate decompression time at typical decompression levels between 3 metres (10 ft) and 9 metres (30 ft), and would save a diver from a direct ascent. The small size of typical very small suit inflation cylinders mean that their contents would quickly be exhausted if breathed, but this is not so of larger ponies.

The thermal conductivity of argon is 68% of that of air or nitrox, hence its use in drysuit inflation. Using argox 20% would slightly degrade this to 74% of that of air.

Argon is far more narcotic (about 2.3 times more) than the cheaper and more readily available nitrogen at depth, so it loses out to nitrogen in all roles as a primary breathing gas. If the maximum operating depth for air due to narcosis is taken to be 40 metres (130 ft), then for 20% argox (20% O2, 80% Ar) it would be 11 metres (36 ft).

Decompression gas

It has been theorised on the basis of the theory of isobaric counterdiffusion that argon, because of its higher molecular mass compared with nitrogen (40 vs. 28 u), may cause less inert gas on-loading, if used as a decompression gas, instead of nitrox.[2] The MOD of argox mixes containing more than about 47% oxygen are limited by oxygen MOD (assuming 1.5 atm ppO2) rather than by argon narcosis MOD. The maximal MOD for argox mixes occurs at 47% oxygen and 53% argon, and is about 73 fsw (22 m). This depth is the theoretical maximum which can be safely attained with any two-component argon/oxygen mix: a larger fraction of oxygen than about 50% will result in oxygen toxicity before this depth, and a larger fraction of argon than about 50% will result in argon narcosis before this depth.

However, as argox is more narcotic than nitrogen (causing it to be more dangerous if a decompression mix is accidentally breathed), and because argox is moderately more expensive than nitrox, and mostly because there has been little research done into the actual (vs. theoretical) physiological aspects of breathing argon during decompression, argox is not currently recommended by any professional agency for this purpose.[3]

Although there is little research relating to divers decompressing using argon mixes, there have been scientific studies of astronauts decompressing using argox. The provisional results of those studies indicated higher levels of decompression sickness when argox was used, rather than pure oxygen; however, using pure oxygen is not an option for decompression at the pressures for which argox would be used in diving, and no direct comparison of argon to nitrogen was done.[4] There is also a certain amount of anecdotal evidence within the diving community that informal experimentation with decompression on argon mixtures has resulted in a high incidence of decompression sickness, but no formal studies.[5]

See also

References

  1. Nuckols, Marshall L; Giblo, J; Wood-Putnam, JL (2008). "Thermal characteristics of diving garments when using argon as a suit inflation gas (abstract)". Undersea and Hyperbaric Medicine. 35 (4). Retrieved 2008-10-24.
  2. D'Aoust BG, Stayton L, Smith LS (September 1980). "Separation of basic parameters of decompression using fingerling salmon". Undersea Biomed Res. 7 (3): 199–209. PMID 7423658. Retrieved 2008-08-28.
  3. Rahn H, Rokitka MA (March 1976). "Narcotic potency of N2, A, and N2O evaluated by the physical performance of mouse colonies at simulated depths". Undersea Biomed Res. 3 (1): 25–34. PMID 1273982. Retrieved 2008-08-28.
  4. Pilmanis Andrew A, Balldin UI, Webb James T, Krause KM (December 2003). "Staged decompression to 3.5 psi using argon-oxygen and 100% oxygen breathing mixtures". Aviat Space Environ Med. 74 (12): 1243–50. PMID 14692466. Retrieved 2008-08-28.
  5. Scubaboard.com (2010-03-25). "Accelerated decompression on an argon mix?". Retrieved 2011-02-02.

External links

This article is issued from Wikipedia - version of the 9/8/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.